Unit Converter

The free Unit Converter handles the conversions behind a Nutrition Facts label: mass from micrograms to pounds, volume from millilitres to US gallons, energy between kcal and kJ (1 kcal = 4.184 kJ), and vitamin A, D and E International Units to mcg or mg with FDA's factors in 21 CFR 101.9(c)(8)(iv).

FDA reference: 1 kcal = 4.184 kJ · Vitamin IU factors from 21 CFR 101.9(c)(8)(iv).

How the unit converter works

Six scales, one method

The converter covers the conversions that come up when building a label: mass, volume, energy, and the International Unit conversions for vitamins A, D and E. Each unit is stored as a fixed number of base units - grams for mass, millilitres for volume, kilocalories for energy - so every conversion is a multiplication into the base and a division out of it.

Both boxes are live. Type in either and the other updates, derived from whichever box you typed in last. Changing the scale resets both units, because a unit from one scale means nothing in another.

Mass and volume

Mass uses the exact avoirdupois figures: 1 oz = 28.3495 g and 1 lb = 453.592 g. Volume uses US customary measures - 1 US fl oz = 29.5735 mL, 1 tbsp = 14.7868 mL, 1 tsp = 4.92892 mL - with pints, quarts and gallons on the same basis.

The cup is the exception: it is 240 mL, the value FDA uses for nutrition labeling, so sixteen tablespoons here come to slightly less than one cup. FDA's labeling definitions in § 101.9(b)(5)(viii) round the small measures too - for nutrition labeling a teaspoon is 5 mL, a tablespoon 15 mL, a fluid ounce 30 mL and an ounce by weight 28 g. The converter uses the exact customary values for everything except the cup, so check which your purpose calls for. Imperial pints and fluid ounces, used in the UK, are different sizes and are not on this scale.

Energy

The Calorie on a US Nutrition Facts panel is the kilocalorie. The converter uses 1 kcal = 4.184 kJ and also lists the small calorie (cal), which is one-thousandth of a kilocalorie.

The small calorie matters mainly as a trap. A value given in cal is a thousand times larger, as a number, than the same energy in kcal, and sources do not always make the distinction obvious. Confirm which unit a figure is in before converting it, rather than assuming every "calorie" is a label Calorie.

Vitamin IU conversions are nutrient-specific

The 2016 Nutrition Facts rules moved vitamins A, D and E from International Units to metric units: micrograms of retinol activity equivalents (RAE) for vitamin A, micrograms for vitamin D and milligrams of alpha-tocopherol for vitamin E. An IU measures biological activity, so its metric equivalent is different for each vitamin.

  • Vitamin D: 1 IU = 0.025 mcg, so 40 IU = 1 mcg.
  • Vitamin A: 1 IU = 0.3 mcg RAE. This factor is for retinol; IU stated for beta-carotene or other provitamin A carotenoids convert differently and are not covered here.
  • Vitamin E: the natural (d-alpha) and synthetic (dl-alpha) forms have different factors and appear as separate units. Choosing the wrong form misstates the value, so take the form from the supplier specification.

Older supplier specifications and pre-2016 labels often still state these vitamins in IU, which is where this conversion is usually needed.

What it does not convert

Mass and volume are separate scales, and nothing here converts between them, because the factor depends on the density of the ingredient. For that, use the volume to weight converter. The same caution applies to ounces: an ounce of weight and a US fluid ounce of volume are different units that only roughly coincide for water.

Displayed results are rounded for reading - whole numbers from 1,000 up, one decimal place from 100, three from 1, five below 1, and scientific notation below 0.001. They are conversions, not label declarations: a value bound for a Nutrition Facts panel still has to be rounded to the increment the regulation sets for that nutrient, which the label generator applies.

For conversions that depend on density, use Volume ↔ Weight; for label serving sizes, see serving size in grams.

Reference information, not legal advice. Requirements change and turn on facts specific to your product - confirm against the current regulation before relying on it.

Common questions

Why does my vitamin conversion look wrong?

Because IU conversions are nutrient-specific, not universal. The 2016 label rules moved vitamins A, D and E from IU to metric: vitamin D is declared in micrograms, vitamin E in milligrams of alpha-tocopherol, vitamin A in micrograms RAE. The factor differs per nutrient and, for vitamins A and E, per source form. A single IU number with no nutrient attached cannot be converted.

Should I use 4.184 or 4.2 for calories to kilojoules?

Use 4.184, the thermochemical factor, and round only at the end. Rounding the factor first introduces error that shows up on higher-energy products. EU and UK labels declare both kJ and kcal, with kJ first, so this conversion is on the critical path for any product crossing the Atlantic.

Can I convert cups to grams?

Not with a single factor, because it depends entirely on what is in the cup. A cup of flour and a cup of honey differ by more than a factor of two. Use the specific gravity or bulk density of the actual material, which is what the Volume to Weight tool is for. Nutrition panels are calculated on mass for exactly this reason.

Does the label use the converted number or the original?

Whichever value you declare must then follow the rounding rules for that nutrient, and the %DV must be consistent with the basis you chose. The order matters: convert first, then round to the increment the format requires, rather than rounding and then converting, which can move a value across a threshold.